Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 4 de 4
Filtre
Ajouter des filtres








Gamme d'année
1.
Annals of Laboratory Medicine ; : 169-173, 2020.
Article Dans Anglais | WPRIM | ID: wpr-762469

Résumé

The GENEDIA MTB/NTM Detection Kit (GENEDIA MTB/NTM; Green Cross Medical Science Corp., Chungbuk, Korea) is a multiplex real-time PCR assay used for differential identification of Mycobacterium tuberculosis complex (MTBC) and nontuberculous mycobacteria (NTM). While the importance of differential identification of MTB/NTM is recognized, there is limited data on the performance of GENEDIA MTB/NTM assay to date. A total of 687 consecutive sputum specimens were cultured and analyzed with the GENEDIA MTB/NTM and GENEDIA MTB assays. Nineteen specimens (2.8%) were MTBC-positive, and 69 (10.0%) were NTM-positive based on mycobacterial culture. All specimens showed concordant results for MTBC using both assays, with a kappa value of 1.00, overall sensitivity of 63.2% (12/19), and specificity of 100% (668/668). The overall NTM sensitivity and specificity were 23.2% (16/69) and 99.7% (616/618) for GENEDIA MTB/NTM. The association between NTM-positivity using GENEDIA MTB/NTM and the diagnosis of NTM pulmonary disease was not statistically significant. In conclusion, the two real-time PCR assays showed similar diagnostic performance for MTBC detection. However, the sensitivity for NTM detection was lower than that for MTBC detection.


Sujets)
Diagnostic , Maladies pulmonaires , Mycobacterium tuberculosis , Mycobacterium , Mycobactéries non tuberculeuses , Réaction de polymérisation en chaine en temps réel , Sensibilité et spécificité , Expectoration
2.
Annals of Laboratory Medicine ; : 57-62, 2020.
Article Dans Anglais | WPRIM | ID: wpr-762454

Résumé

As various linezolid resistance mechanisms have been identified in methicillin-resistant Staphylococcus aureus (MRSA), we investigated the molecular characteristics of MRSA with elevated linezolid minimum inhibitory concentrations (MICs), using the VITEK 2 system (bioMérieux, Marcy-l'Étoile, France). Twenty-seven MRSA isolates from 14 patients exhibiting linezolid MICs ≥8 µg/mL were examined by broth microdilution (BMD) test as well as by sequencing for mutations in the 23S rRNA gene or ribosomal proteins (L3, L4, and L22) and the presence of the optrA, cfr, and cfr(B) genes. Of the 27 isolates, four (14.8%) from one patient were confirmed as linezolid resistant by BMD and harbored a 23S rRNA T2500A mutation. The remaining 23 were confirmed as linezolid susceptible, indicating that the linezolid-resistant results were major errors generated by VITEK 2. The most commonly detected mutation (19/27, 70.4%), L3 Gly152Asp, was detected in only linezolid-susceptible isolates. No isolates contained optrA, cfr, or cfr(B) or any L4 or L22 protein alterations. Our results show that the 23S rRNA T2500A mutation was mainly associated with linezolid resistance, while the L3 Gly152Asp mutation was not related to linezolid resistance. A confirmatory test is recommended for VITEK 2 linezolid-resistant results owing to the high probability of false resistant results.


Sujets)
Humains , Gènes d'ARN ribosomique , Corée , Linézolide , Résistance à la méticilline , Staphylococcus aureus résistant à la méticilline , Tests de sensibilité microbienne , Protéines ribosomiques , ARN ribosomique 23S
3.
Annals of Laboratory Medicine ; : 63-67, 2020.
Article Dans Anglais | WPRIM | ID: wpr-762453

Résumé

As 16S ribosomal RNA (rRNA)-targeted sequencing can detect DNA from non-viable bacteria, it can be used to identify pathogens from clinical samples even in patients pretreated with antibiotics. We compared the results of 16S rRNA-targeted sequencing and culture for identifying bacterial species in normally sterile body fluid (NSBF): cerebrospinal, pericardial, peritoneal and pleural fluids. Over a 10-year period, a total of 312 NSBF samples were evaluated simultaneously using 16S rRNA-targeted sequencing and culture. Results were concordant in 287/312 (92.0%) samples, including 277 (88.8%) negative and 10 (3.2%) positive samples. Of the 16 sequencing-positive, culture-negative samples, eight showed clinically relevant isolates that included Fusobacterium nucleatum subsp. nucleatum, Streptococcus pneumoniae, and Staphylococcus spp. All these samples were obtained from the patients pretreated with antibiotics. The diagnostic yield of 16S rRNA-targeted sequencing combined with culture was 11.2%, while that of culture alone was 6.1%. 16S rRNA-targeted sequencing in conjunction with culture could be useful for identifying bacteria in NSBF samples, especially when patients have been pretreated with antibiotics and when anaerobic infection is suspected.


Sujets)
Humains , Antibactériens , Bactéries , Liquides biologiques , ADN , Fusobacterium nucleatum , ARN ribosomique 16S , Staphylococcus , Streptococcus pneumoniae
4.
Annals of Clinical Microbiology ; : 90-95, 2019.
Article Dans Anglais | WPRIM | ID: wpr-816601

Résumé

BACKGROUND: A major complication of peritoneal dialysis (PD) is peritonitis, and bacterial culture of PD effluent in a blood culture bottle is the preferred technique for diagnosis of peritonitis. In this study, we compared dialysate inoculation and culture using the BacT/AlerT® Fastidious Antimicrobial Neutralization Plus blood culture bottles (FAN Plus; bioMérieux, France) to the conventional centrifugation culture method.METHODS: A total of 170 PD effluents were simultaneously processed by the conventional centrifugation culture method and by culture using FAN Plus media with two different inoculation procedures: inoculation after centrifugation and direct bedside inoculation.RESULTS: Of the 52 cultures that were positive on at least one of the culture methods, 27 samples were positive on conventional centrifugation. However, 46 samples showed growth following inoculation into the FAN Plus media after centrifugation, and 47 samples were positive on the direct FAN Plus inoculation method. Using the case definition for PD peritonitis to classify samples, sensitivity of the conventional method was 50.0% (95% CI, 33.7–66.3%), whereas the sensitivity of the FAN Plus media was 78.9% (95% CI, 62.2–89.9%) by inoculation after centrifugation and 86.8% (95% CI, 71.1–95.1%) by direct inoculation. Use of both inoculation methods with FAN Plus media resulted in 92.1% sensitivity (95% CI, 89.2–99.9%).CONCLUSION: Culture using FAN Plus media demonstrated a superior bacterial recovery rate to the conventional centrifugation culture method. A combination of the two inoculation methods with FAN Plus media is recommended for the best diagnostic yield, while direct inoculation alone can be useful due to its simplicity and cost-effectiveness.


Sujets)
Centrifugation , Milieux de culture , Diagnostic , Méthodes , Dialyse péritonéale , Péritonite
SÉLECTION CITATIONS
Détails de la recherche